An SKLN8 counterflow cooler stands 4.1 m tall on a 3.4 × 2.7 m base and weighs 2,280 kg empty. Fill its 8 m³ chamber with pellets and the load on your floor roughly triples. That gap between the number on the spec sheet and the number your structural engineer needs is where most cooler layout planning goes wrong. This guide shows how to read the dimension and weight data for the SKLN and SKLB series, how to estimate the real floor load, and what to check before you fix a position for the cooler in your building.
Plan the cooler around its operating weight, not its net weight. Net weight is the machine alone. Operating weight adds the pellets held in the chamber, and for a typical pellet feed that product load is larger than the machine itself. Then check three things before you fix the position: plan area, total height including the inlet and duct connections, and clear access to the front inspection door and the side observation window. Get the supplier's layout drawing before you pour a foundation.
Three terms matter here. Footprint is the plan area the machine covers, which you get by multiplying the listed length by the listed width. Net weight is the weight of the empty machine. Effective volume is the space inside the chamber that holds product, and it is what turns an empty machine into a loaded one. The listed height is the machine only, so add room for the feed inlet, the air connections, and a safe working clearance.
The SKLN line covers eight models from 1 T/H to 35 T/H. The plan area used later in this guide is calculated from the listed length and width.
| Model | Slide valve discharge motor power (kW) | Capacity (t/h) | Cooling volume (m³) | Weight (kg) | Length × Width × Height (mm) |
|---|---|---|---|---|---|
| SKLN1.5 | 1.5 | 1-2.5t/h | 1.5 | 980 | 2000*1400*2850 |
| SKLN2.5 | 1.5 | 2.5-5t/h | 2.5 | 1170 | 2300*1700*3200 |
| SKLN4 | 2.2 | 5-10t/h | 4 | 1740 | 2800*2200*3550 |
| SKLN6 | 3 | 10-15t/h | 6 | 2004 | 3300*2200*4050 |
| SKLN8 | 4 | 15-20t/h | 8 | 2280 | 3400*2700*4100 |
| SKLN10 | 4 | 20-25t/h | 10 | 3000 | 3900*2700*4200 |
| SKLN12 | 4 | 25-30t/h | 12 | 3600 | 3900*3200*4450 |
| SKLN15 | 5.5 | 30-35t/h | 15 | 4300 | 3930*3570*5360 |
At the same capacity class, the SKLB tipping cooler needs about 2 to 10 percent more floor area than the SKLN in most sizes, and it weighs 2 to 20 percent more. The extra weight is consistent with its hydraulic discharge and jacketed insulation box. At the top size the two share the same listed footprint of 3930 × 3570 mm. The listed SKLB6 base is notably wider than its neighbours, so confirm that model against the supplier's drawing before you commit to a layout.
| Size | SKLN Area (m²) | SKLB Area (m²) | SKLN Weight (kg) | SKLB Weight (kg) | SKLB Weight vs SKLN |
|---|---|---|---|---|---|
| 1.5 | 2.80 | 3.08 | 980 | 1000 | +2.0% |
| 2.5 | 3.91 | 4.28 | 1170 | 1400 | +19.7% |
| 4 | 6.16 | 6.53 | 1740 | 2000 | +14.9% |
| 6 | 7.26 | 10.87 | 2004 | 2200 | +9.8% |
| 8 | 9.18 | 9.49 | 2280 | 2510 | +10.1% |
| 10 | 10.53 | 11.00 | 3000 | 3250 | +8.3% |
| 12 | 12.48 | 12.74 | 3600 | 3850 | +6.9% |
| 15 | 14.03 | 14.03 | 4300 | 4690 | +9.1% |
Operating weight equals net weight plus the product in the chamber. The product load is the effective volume multiplied by the pellets' bulk density. The example below assumes 0.6 t/m³ for illustration, so replace it with your own measured bulk density before you use the result.
| Model | Net Weight (kg) | Product in Chamber (kg) | Operating Weight (kg) | Multiple of Net Weight | Average Load (kg/m²) |
|---|---|---|---|---|---|
| SKLN4 | 1740 | 2400 | 4140 | 2.4× | 672 |
| SKLN8 | 2280 | 4800 | 7080 | 3.1× | 771 |
| SKLN12 | 3600 | 7200 | 10800 | 3.0× | 865 |
| SKLN15 | 4300 | 9000 | 13300 | 3.1× | 948 |
The average load is the operating weight divided by the plan area. It is a quick screening number, not a design value. The machine does not rest evenly on its whole base, because the weight travels through its support points. Give your structural engineer the supplier's drawing and the operating weight, and let them size the foundation from the actual support locations.
Listed heights run from 2.85 m on the SKLN1.5 to 5.36 m on the SKLN15. That is the machine alone. A cooler takes pellets in at the top, so in a gravity-fed layout the pelletizer or its conveying link has to sit above the inlet. Count the vertical room for that connection, for the air duct, and for lifting out parts during maintenance, and compare the total against the clear height under your beams.
The SKLN has a front inspection door and a side observation window, and both are only useful if people can reach them. Keep a clear path in front of the door and a line of sight to the window. The SKLB adds a hydraulic discharge system. The standard model is not equipped with an insulation jacket. The insulation jacket can be supplied according to product requirements, so leave room to reach the hydraulic unit for fluid checks.
Sizing the foundation from net weight is the most common error. The product load can be two to three times the machine's own weight in the example above, so a foundation checked only against the empty machine is under-designed.
Boxing in the inspection door or window happens when the cooler is pushed against a wall or a neighbouring machine to save floor space. The space saved costs you easy inspection every day afterwards.
Counting only the listed height leaves no room for the inlet spout, the air connections, or a safe working clearance. Add those before you compare the machine to your ceiling or beam height.
Choosing a model by footprint alone can backfire when two sizes have similar bases. Check the capacity range as well. A cooler running near the bottom of its range holds the product for longer, and a cooler running above its range cools less well.
Choose the model by capacity first, using your pelletizer's peak output, and use the footprint and weight data to test whether the building can take it. If the space is tight, compare SKLN and SKLB at the same size, and choose on the product you make rather than on the base size alone, since the two differ by only a few percent in most sizes.
Ask the supplier for three documents before you order: a layout drawing with support points, the operating weight at your bulk density, and the clearances needed for the inspection door and for maintenance. A quote that gives only the table above leaves those questions open.
No. Net weight is the empty machine. When the chamber is full, the product adds a load that can be two to three times the machine's own weight, depending on the pellets' bulk density. Use the operating weight for foundation planning.
The listed data shows the SKLB weighing about 2 to 20 percent more across most sizes. The SKLB adds a hydraulic discharge system. The standard model is not equipped with an insulation jacket. The insulation jacket can be supplied according to product requirements, which is consistent with the extra weight. Ask the supplier for a breakdown if the difference matters for your structure.
You can, but only on a side that has no door or window you need. The SKLN has a front inspection door and a side observation window, so keep those faces clear. A cooler you cannot inspect easily is one that gets inspected less often.
There is no single figure, because it depends on your inlet connection, your air duct route, and how you plan to lift parts out. Ask the supplier for a layout drawing that shows those connections and compare the total with your clear height.
Written by: Yuda Machinery Engineering Team
Based on years of experience in feed machinery manufacturing, equipment design and overseas project installation.
Supply feed, fertilizer & biomass core equipment and full turnkey lines. Factory area: 34,500 sq.m. Exported to 70+ countries.